SCIENTIFIC METHOD

From CAMS EAC4
to an exact project location.

CAMS Air Quality automates the retrieval and scientific processing workflow while keeping the source, transformation steps and quality checks explicit.

3-hourly EAC40.75° source gridExact-site interpolationµg/m³ outputs
PROCESSING WORKFLOW

Six transparent stages.

The platform does not hide the scientific method behind a single download button. Each stage corresponds to a defined processing step.

01

Configure the extraction

Select the project coordinates, historical period and pollutants available under the account plan.

02

Retrieve CAMS EAC4

The worker prepares the required surface and model-level requests against the Copernicus Atmosphere Data Store.

03

Interpolate the exact site

The four surrounding 0.75° grid points are used for bilinear interpolation to the requested latitude and longitude.

04

Convert concentrations

Surface particulate diagnostics are converted to µg/m³; supported gaseous species use model-level-60 meteorology to estimate air density before conversion.

05

Run QA/QC

The workflow checks expected timestamps, missing and duplicate records, interpolation fallback, NaN, negative and exact-zero values.

06

Build outputs

Validated results are assembled into data files, statistics, analytics, request traceability and editable Word reporting.

SPATIAL METHOD

Exact-site bilinear interpolation

The requested coordinates are located within the surrounding CAMS grid cell. Concentrations at the four bounding grid points are combined using bilinear interpolation, rather than simply returning the nearest model grid point.

GAS CONVERSION

Air-density aware conversion

For supported gaseous pollutants, model-level-60 temperature and specific humidity are combined with surface pressure to estimate air density before converting mass-mixing-ratio fields to µg/m³.

PARTICULATE MATTER

Surface concentration diagnostics

PM₁₀, PM₂.₅ and PM₁ surface diagnostics are handled as mass concentrations and converted to µg/m³ for the final processed time series.

TRACEABILITY

Keep the request with the result

Request metadata, source-grid context, selected pollutants, period and processing outputs remain tied to the run so users can review how a dataset was produced.

QUALITY ASSURANCE

Checks before the data is presented.

RESULTS

More than a raw download.

Data

3-hourly processed values plus daily and monthly summaries.

Statistics

Mean, extrema, percentiles, variability and pollutant-specific summaries.

Analytics

Temporal trends, distributions, diurnal profiles and climatological views.

Reporting

Company/project branding, tables, figures and editable DOCX output.

SCIENTIFIC CONTEXT

CAMS EAC4 is regional modelled background data.

It is useful for historical atmospheric context and regional background assessment. It is not on-site monitoring and does not replace direct regulatory measurements where those are required.

Copernicus Atmosphere Data Store ↗